BMCPK - RESOL 1-1-1 TRICHLOROETHANE, 04580

  • MSDS: BMCPK
  • Manufacturer: NORTH EAST SOLVENTS CORP
  • Product Name: RESOL 1-1-1 TRICHLOROETHANE, 04580
  • National Stock Number: 6810-00N025597
Product Identification

Product ID:RESOL 1-1-1 TRICHLOROETHANE, 04580
MSDS Date:12/09/1987
FSC:6810
NIIN:00N025597
MSDS Number: BMCPK

Responsible Party
NORTH EAST SOLVENTS CORP
221 SUTTON ST
NO ANDOVER, MA 01845
US

Emergency Phone: 617-683-1002

Info Phone: 617-683-1002

Cage: 47912

Contractor
NORTH EAST SOLVENTS CORP
NO ANDOVER, MA 01845 US

Telephone: 617-683-1002

Cage: 47912

Ingredients

AREAS WITH POOR VENTILATION.

RTECS: 9999999ZZ


DISCOURAGED AND MAY BE ILLEGAL. CONSULT

RTECS: 9999999ZZ


USE POSITIVE PRESSURE SCBA. IN CONFINED OR POORLY

RTECS: 9999999ZZ


CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

RTECS: 9999999ZZ


ETHANE, 1,1,1-TRICHLORO-;(1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 100%

OSHA PEL 350 PPM;450 STEL

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CHLOROCARBON MATLS HAVE PRODUCED SENSIT OF

RTECS: 9999999ZZ


EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY

RTECS: 9999999ZZ


IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO

RTECS: 9999999ZZ


SYS EFTS, DECISION OF WHETHER TO INDUCE

RTECS: 9999999ZZ


SUGGEST ENDOTRACHEAL &/OR ESOPHAGUL CNTRL. DANGER

RTECS: 9999999ZZ


CONSIDERING EMPTYING STOMACH. EXPOS MAY INCR

RTECS: 9999999ZZ


ABSOLUTELY NEC. NO SPECIFIC ANTIDOTE. SUPPORTIVE

RTECS: 9999999ZZ


ASSISTANCE.SHOULD NOT BE PACKAGED IN ALUMINUM

RTECS: 9999999ZZ


IN AN AEROSOL CAN. ALUMINUM IS NOT ACCEPTABLE MATL OF

RTECS: 9999999ZZ


TANKS THAT CNTN 1-1-1-TRICHLOROETHANE. METALLIC

RTECS: 9999999ZZ


IN AREA OF USE. DO NOT USE IN GEN VICIN OF ARC

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL RAT) 10,000 MG/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:MAY CAUSE PAIN. MAY CAUSE SLIGHT
TRANSIENT (TEMPORARY) IRRIT W/SLIGHT TRANSIENT CORNEAL INJURY.
VAPORS MAY IRRIT. SKIN:PRLNGD/RPTD EXPOS MAY CAUSE IRRIT. RPTD CONT
MAY CAUSE DRYING OR FLAKING. SIN GLE PRLNGD EXPOS NOT LIKELY TO
RSLT IN ABSORPTION IN HARMFUL AMTS. INGEST:SINGLE DOSE ORAL TOX IS
LOW. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:IF ASPIR (LIQ ENTERS LUNG), MAY BE
RAPIDLY ABSORBED THROUGH LUNGS & RSLT IN INJURY TO OTHER BODY SYS.
INHAL:MIN ANESTH OR NARCOTIC EFTS MAY BE SEEN IN RANGE OF 500-1000
PPM TRICHLOROETHANE. PROGRESSIVELY HIGHER LEVELS OVER 1000 PPM
MAY CAUSE DIZZ, DRUNKENESS; CONC AS LOW AS 10,000 PPM CAN CAUSE
UNCON (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:IRRIGATE IMMED W/WATER FOR AT LEAST 15 MINS. SKIN:WASH
OFF IN FLOWING WATER OR SHOWER. REMOVE CONTAM CLTHG & WASH BEFORE
REUSE. INGEST:DO NOT INDUCE VOMIT. CALL MD OR TAKE TO EMERC
FACILITY IMMED. INHAL:MOVE TO FRESH AIR. IF NOT BRTHG,GIVE
MOUTH-TO-MOUTH RESUSCITATION. IF BRTHG DFCLT, GIVE O*2. CALL MD.
NOTE TO MD:BECAUSE RAPID ABSORPTION MAY OCCUR THROUGH LUNGS IF
ASPIR & CAN CAUSE (ING 5)

Fire Fighting

Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:WATER FOG, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:SMALL LEAKS:MOP UP, WIPE UP OR SOAK UP
IMMEDIATELY. REMOVE TO OUT-OF-DOORS. LARGE SPILLS:EVACUATE AREA.
CONTAIN LIQUID; TRANSFER TO CLOSED METAL CONTAINERS. KEEP OUT OF
WATER SUPPLIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HANDLE WITH REASONABLE CARE. STORE IN
COOL, DRY PLACE.
Other Precautions:CONC VAPS OF PROD ARE HEAVIER THAN AIR & WILL COLLECT
IN LOW AREAS SUCH AS PITS, DEGREASERS, STORAGE TANKS, & OTHER
CONFINED AREAS. DO NOT ENTER THESE AREAS WHERE VAP OF PROD ARE
SUSPECTED UNLESS SCBA IS USED & OBSERVER PRESENT FOR (ING 9)

Exposure Controls

Respiratory Protection:ALL RESPS MUST BE NIOSH/MSHA APPRVD. ATMOSPHERIC
LEVELS SHOULD BE MAINTAINED BELOW EXPOS GUIDELINE.WHEN RESP PROT
REQ FOR CERTAIN OPERS, USE AIR-PURIFYING RESP. FOR EMERG & OTHER
CNDTNS WHERE EXPOS GU IDELING MAY BE GREATLY EXCEEDED,(ING 16)
Ventilation:CNTRL AIRBORNE CONC BELOW EXPOS GUIDELINE. USE ONLY W/ADEQ
VENT. LOC EXHST MAY BE NEC. LETHAL CONC MAY EXIST IN (ING 18)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WHEN PROLONGED OR FREQUENTLY REPEATED
CONTACT COULD OCCUR, BOOTS, APRON, OR FULL BODYSUIT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MATLS TO AVOID:PRLNGD CONT WITH, OR STORE IN, ALUMINUM/ITS ALLOYS.
METALLIC ALUMINIM W/ZINC POWDERS SHOULD BE AVOIDED. EFTS OF
OVEREXP:& DEATH. IN CONFINED OR POORLY VENTILATED AREAS, VAPORS
WHICH REA DILY ACCUMULATE CAN CAUSE UNCON & DEATH. HIGH LEVELS MAY
ALSO CAUSE CARDIAC ARRTHIMIAS (IRREGULAR HEARTBEATS). (ING 2)

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:165F,74C
Vapor Pres:100 @ 20C
Vapor Density:4.6
Spec Gravity:1.32 @ 25C
Solubility in Water:0.07GM/100GM @ 25C
Appearance and Odor:CLEAR COLORLESS LIQUID WITH MILDLY SWEET ODOR

Stability

Stability Indicator/Materials to Avoid:YES
WATER:LONG TERM CONTACT CAN DEPLETE STABILIZERS FOLLOWED BY SLOW
HYDROLYSIS PRODUCING CORROSIVE ACID. AVOID (SUPP DATA)
Stability Condition to Avoid:OPEN FLAMES, WELDING ARCS OR OTHER HIGH
TEMPERATURE SOURCES WHICH INCLUDE THERMAL DECOMPOSITION.
Hazardous Decomposition Products:HCL & VERY SMALL AMOUNTS OF PHOSGENE &
CHLORINE.

Disposal

Waste Disposal Methods:WHEN DISP OF UNUSED CONTENTS, PREF OPTIONS ARE
TO SEND TO LICENSED RECLAIMER, PERMITTED INCIN, OR TO EVAP VERY
SMALL QTYS I/A/W LOC, STATE & FED REGS, UNCL SUBTITLE C OF RCRA.
DUMPING INTO SEWERS, ON GROUND, OR INTO ANY BODY OF WATER IS (ING
15)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.